G621 - Gas Proving System (1/2″ BSP)

G621 - Gas Proving System (1/2″ BSP)


 
 
 
 
 
 
 
 
  • BS6173 and IGE/UP/2 2nd Edition (July 2008) compliant weep proving system for kitchens and laboratories
  • 1/2″ BSP (15mm) threaded connection
  • Also available with 15mm copper fittings
  • Simple to install & easy to operate
  • Air pressure switch or current monitor interlocks
  • Remote emergency stop facility
  • Remote status indication - volt free contacts
  • G621 valve assembly is pre-wired
  • 230 Volt supply
  • Up to 200 mbar inlet pressure

Click here for more information

The Duomo Gas Safestart (G621) weep bypass system, securely isolates and safely re-establishes the gas supply to any area which relies on manual isolation of gas outlets. The Duomo Gas Safestart is used in hotels, fast food restaurants, schools, colleges, scientific research laboratories and canteens throughout Europe. Safestart protects personnel and property from damage caused by gas leaks.

Product datasheet

Wiring Diagram (when used with KS22 Trio)

Wiring Diagram (when used with KS23 Labstart)

Wiring Diagram (when used with KS10 Control Panel)

Wiring Diagram (when used with KS21 Keyswitch)

[Top]


G621 - Gas Proving System (3/4″ BSP)

G621 - Gas Proving System (3/4″ BSP)


 
 
 
 
 
 
 
 
  • BS6173 and IGE/UP/2 2nd Edition (July 2008) compliant weep proving system for kitchens and laboratories 
  • 3/4″ BSP (20mm) threaded connection
  • Also available with 22mm copper fittings
  • Simple to install & easy to operate
  • Air pressure switch or current monitor interlocks
  • Remote emergency stop facility
  • Remote status indication - volt free contacts
  • G621 valve assembly is pre-wired
  • 230 Volt supply
  • Up to 200 mbar inlet pressure

Click here for more information

The Duomo Gas Safestart (G621) weep bypass system, securely isolates and safely re-establishes the gas supply to any area which relies on manual isolation of gas outlets. The Duomo Gas Safestart is used in hotels, fast food restaurants, schools, colleges, scientific research laboratories and canteens throughout Europe. Safestart protects personnel and property from damage caused by gas leaks.

Product datasheet

Wiring Diagram (when used with KS22 Trio)

Wiring Diagram (when used with KS23 Labstart)

Wiring Diagram (when used with KS10 Control Panel)

Wiring Diagram (when used with KS21 Keyswitch)

[Top]


G621 - Gas Proving System (1″ BSP)

G621 - Gas Proving System (1″ BSP)


 
 
 
 
 
 
 
 
  • BS6173 and IGE/UP/2 2nd Edition (July 2008) compliant weep proving system for kitchens and laboratories
  • 1″ BSP (25mm) threaded connection
  • Also available with 28mm copper fittings
  • Simple to install & easy to operate
  • Air pressure switch or current monitor interlocks
  • Remote emergency stop facility
  • Remote status indication - volt free contacts
  • G621 valve assembly is pre-wired
  • 230 Volt supply
  • Up to 200 mbar inlet pressure

Click here for more information

The Duomo Gas Safestart (G621) weep bypass system, securely isolates and safely re-establishes the gas supply to any area which relies on manual isolation of gas outlets. The Duomo Gas Safestart is used in hotels, fast food restaurants, schools, colleges, scientific research laboratories and canteens throughout Europe. Safestart protects personnel and property from damage caused by gas leaks.

Product datasheet

Wiring Diagram (when used with KS22 Trio)

Wiring Diagram (when used with KS23 Labstart)

Wiring Diagram (when used with KS10 Control Panel)

Wiring Diagram (when used with KS21 Keyswitch)

[Top]


G621 - Gas Proving System (1 1/4″ BSP)

G621 - Gas Proving System (1 1/4″ BSP)


 
 
 
 
 
 
 
 
  • BS6173 and IGE/UP/2 2nd Edition (July 2008) compliant weep proving system for kitchens and laboratories 
  • 1 1/4″ BSP (35mm) threaded connection
  • Also available with 32mm copper fittings
  • Simple to install & easy to operate
  • Air pressure switch or current monitor interlocks
  • Remote emergency stop facility
  • Remote status indication - volt free contacts
  • G621 valve assembly is pre-wired
  • 230 Volt supply
  • Up to 200 mbar inlet pressure

Click here for more information

The Duomo Gas Safestart (G621) weep bypass system, securely isolates and safely re-establishes the gas supply to any area which relies on manual isolation of gas outlets. The Duomo Gas Safestart is used in hotels, fast food restaurants, schools, colleges, scientific research laboratories and canteens throughout Europe. Safestart protects personnel and property from damage caused by gas leaks.

Product datasheet

Wiring Diagram (when used with KS22 Trio)

Wiring Diagram (when used with KS23 Labstart)

Wiring Diagram (when used with KS10 Control Panel)

Wiring Diagram (when used with KS21 Keyswitch)

[Top]


G621 - Gas Proving System (1 1/2″ BSP)

G621 - Gas Proving System (1 1/2″ BSP)


 
 
 
 
 
 
 
 
  • BS6173 and IGE/UP/2 2nd Edition (July 2008) compliant weep proving system for kitchens and laboratories 
  • 1 1/2″ BSP (40mm) threaded connection
  • Also available with 32mm copper fittings
  • Simple to install & easy to operate
  • Air pressure switch or current monitor interlocks
  • Remote emergency stop facility
  • Remote status indication - volt free contacts
  • G621 valve assembly is pre-wired
  • 230 Volt supply
  • Up to 200 mbar inlet pressure

Click here for more information

The Duomo Gas Safestart (G621) weep bypass system, securely isolates and safely re-establishes the gas supply to any area which relies on manual isolation of gas outlets. The Duomo Gas Safestart is used in hotels, fast food restaurants, schools, colleges, scientific research laboratories and canteens throughout Europe. Safestart protects personnel and property from damage caused by gas leaks.

Product datasheet

Wiring Diagram (when used with KS22 Trio)

Wiring Diagram (when used with KS23 Labstart)

Wiring Diagram (when used with KS10 Control Panel)

Wiring Diagram (when used with KS21 Keyswitch)

[Top]


G621 - Gas Proving System (2″ BSP)

G621 - Gas Proving System (2″ BSP)


 
 
 
 
 
 
 
 
  • BS6173 and IGE/UP/2 2nd Edition (July 2008) compliant weep proving system for kitchens and laboratories 
  • 2″ BSP (50mm) threaded connection
  • Simple to install & easy to operate
  • Air pressure switch or current monitor interlocks
  • Remote emergency stop facility
  • Remote status indication - volt free contacts
  • G621 valve assembly is pre-wired
  • 230 Volt supply
  • Up to 200 mbar inlet pressure

Click here for more information

The Duomo Gas Safestart (G621) weep bypass system, securely isolates and safely re-establishes the gas supply to any area which relies on manual isolation of gas outlets. The Duomo Gas Safestart is used in hotels, fast food restaurants, schools, colleges, scientific research laboratories and canteens throughout Europe. Safestart protects personnel and property from damage caused by gas leaks.

Product datasheet

Wiring Diagram (when used with KS22 Trio)

Wiring Diagram (when used with KS23 Labstart)

Wiring Diagram (when used with KS10 Control Panel)

Wiring Diagram (when used with KS21 Keyswitch)

[Top]


G621 - Gas Proving System (2 1/2″ Flanged)

G621 - Gas Proving System (2 1/2″ Flanged)


 
 
 
 
 
 
 
 
  • BS6173 and IGE/UP/2 2nd Edition (July 2008) compliant weep proving system for kitchens and laboratories 
  • 2 1/2″ (65mm) flanged connection
  • Simple to install & easy to operate
  • Air pressure switch or current monitor interlocks
  • Remote emergency stop facility
  • Remote status indication - volt free contacts
  • G621 valve assembly is pre-wired
  • 230 Volt supply
  • Up to 200 mbar inlet pressure

Click here for more information

The Duomo Gas Safestart (G621) weep bypass system, securely isolates and safely re-establishes the gas supply to any area which relies on manual isolation of gas outlets. The Duomo Gas Safestart is used in hotels, fast food restaurants, schools, colleges, scientific research laboratories and canteens throughout Europe. Safestart protects personnel and property from damage caused by gas leaks.

Product datasheet

Wiring Diagram (when used with KS22 Trio)

Wiring Diagram (when used with KS23 Labstart)

Wiring Diagram (when used with KS10 Control Panel)

Wiring Diagram (when used with KS21 Keyswitch)

[Top]


G621 - Gas Proving System (3″ Flanged)

G621 - Gas Proving System (3″ Flanged)


 
 
 
 
 
 
 
 
  • BS6173 and IGE/UP/2 2nd Edition (July 2008) compliant weep proving system for kitchens and laboratories
  • 3″ (80mm) flanged connection
  • Simple to install & easy to operate
  • Air pressure switch or current monitor interlocks
  • Remote emergency stop facility
  • Remote status indication - volt free contacts
  • G621 valve assembly is pre-wired
  • 230 Volt supply
  • Up to 200 mbar inlet pressure

Click here for more information

The Duomo Gas Safestart (G621) weep bypass system, securely isolates and safely re-establishes the gas supply to any area which relies on manual isolation of gas outlets. The Duomo Gas Safestart is used in hotels, fast food restaurants, schools, colleges, scientific research laboratories and canteens throughout Europe. Safestart protects personnel and property from damage caused by gas leaks.

Product datasheet

Wiring Diagram (when used with KS22 Trio)

Wiring Diagram (when used with KS23 Labstart)

Wiring Diagram (when used with KS10 Control Panel)

Wiring Diagram (when used with KS21 Keyswitch)

[Top]


G621 - Gas Proving System (4″ Flanged)

G621 - Gas Proving System (4″ Flanged)


 
 
 
 
 
 
 
 
  • BS6173 and IGE/UP/2 2nd Edition (July 2008) compliant weep proving system for kitchens and laboratories
  • 3″ (80mm) flanged connection
  • Simple to install & easy to operate
  • Air pressure switch or current monitor interlocks
  • Remote emergency stop facility
  • Remote status indication - volt free contacts
  • G621 valve assembly is pre-wired
  • 230 Volt supply
  • Up to 200 mbar inlet pressure

Click here for more information

The Duomo Gas Safestart (G621) weep bypass system, securely isolates and safely re-establishes the gas supply to any area which relies on manual isolation of gas outlets. The Duomo Gas Safestart is used in hotels, fast food restaurants, schools, colleges, scientific research laboratories and canteens throughout Europe. Safestart protects personnel and property from damage caused by gas leaks.

Product datasheet

Wiring Diagram (when used with KS22 Trio)

Wiring Diagram (when used with KS23 Labstart)

Wiring Diagram (when used with KS10 Control Panel)

Wiring Diagram (when used with KS21 Keyswitch)

[Top]

Latest News